IMPORTANT NOTES:It is essential that you select the correct model based on CFM (m3/m) requirements, not air inlet size (A). For assistance with selecting the correct model for your equipment, see our online Series 9000 Sizing Wizard. If you cannot determine the correct precleaner from this matrix, please contact our technical support department for assistance

You must allow adequate clearance between the hood and the base of the precleaner for it to function properly. There are extension pipes and other adaptation parts available to increase clearance when necessary. Contact your Dealer or Sy-Klone for details.

>> Series 9000 Product Information

The sizing matrix has been recently updated, and it applies to electronically and non electronically controlled engines. Efforts have been made to take into consideration the more restrictive components found on current air intake systems. Precleaner sizing recommendations balance initial restriction requirements with precleaning efficiency to provide the longest filter life and best engine performance. Recent additions to the Series 9000 product line allows for precision in the sizing of precleaners that was previously not possible. This matrix replaces all previous sizing matracies.

Model Dimensions in inches or millimeters
(ID = inner diameter)
Airflow: CFM or m3/m Weight
lb or kg
Min Hood
Clearance

inches or mm
A B C D E D+E Min Max
9000
in->
2.015 ID 4.5 0.8 0.5 2.5 3.00 10 50 0.50 2.0
mm-> 51.18 ID 114.3 20.3 12.7 63.5 76.2 0.28 1.42 0.2268 50.8
9000R
in->
3.021 ID 6.7 1.2 0.5 3.7 4.2 50 120 0.80 3.0
mm-> 76.73 ID 170.2 30.5 12.7 94.0 106.7 1.42 3.40 0.3629 76.2
9001
in->
4.031 ID 8.507 2.6 0.9 5.8 6.3 100 275 2.6 4.0
mm-> 102.38 ID 216.1 66.1 22 146.5 159.7 2.83 7.79 1.179 101.6
9001R
in->
4.031 ID 8.507 2.603 0.9 5.768 6.288 275 350 2.4 4.0
mm-> 102.38 ID 216.1 66.1 22 146.5 159.7 7.79 9.91 1.089 101.6
9005
in->
5.03 ID 10.63 2.97 0.9 7.03 7.90 350 500 2.0 5.0
mm-> 127.29 ID 270.05 75.44 22 178.56 200.66 9.91 14.16 .91 127.0
9002
in->
6.042 ID 13.1 4.0 2.5 8.6 11.1 500 650 6.5 6.0
mm-> 153.74 ID 331.8 102.0 63.5 218.5 282.0 14.16 18.41 2.948 152.4
9002R
in->
6.042 ID 13.1 4.0 2.5 8.6 11.1 650 800 6.4 6.0
mm-> 153.74 ID 331.8 102.0 63.5 218.5 282.0 18.41 22.65 2.903 152.4
9003
in->
8.062 ID 18.0 5.3 3.0 11.4 14.4 800 1150 11.8 8.0
mm-> 204.77 ID 457.2 135.7 76.2 290.5 366.7 22.65 32.56 5.352 203.2
9004
in->
8.062 ID 18.0 5.3 3.0 11.4 14.4 1150 1400 11.0 8.0
mm-> 204.77 ID 457.2 135.7 76.2 290.5 366.7 32.56 39.64 4.99 203.2

photo of all precleanersAirflows above 1400 CFM (39.64 m3/m) can be handled with multiple unit installations. Please contact Sy-Klone for assistance.Photo of D10R with multiple unit installation.