Electronic Pressure Monitor System

An ESSENTIAL Component of a Cab Air Quality System

RESPA systems work in conjunction with the machine’s HVAC system to pressurize the operator cab. To maintain proper function, all pressurized cabs should have a pressure sensor. This alerts the operator to both increased exposure to contaminants and conditions that burden the HVAC system. When the cab does not hold pressure, it is time to service the seals in the cab or replace the RESPA’s filter.In order to insure that you get RESPA’s advertised extended HVAC service intervals, it is critical to keep the air in the cab as clean as possible. When the cab loses pressure, unfiltered outside air is drawn into the cab creating a ”vacuum cleaner bag” environment with potentially unhealthy respiratory conditions for the operator. The recirculation blower draws the contaminated air over the evaporator coils which collect the contaminants and clog the coils, resulting in HVAC failure. A Pressure Monitor System is recommended for use with Sy-Klone’s Cab Air Quality Systems.

Pressure Monitor Features:

RESPA Pressure Sensor

1 LED Alarm: The lighted indicator illuminates whenever the cab pressure drops below the preset minimum threshold for more than ten seconds. This feature cannot be disabled. The ten second delay allows for normal door opening and closing without setting off the alarm.
2 Low Pressure Signal Alarm: This feature is internal in all units. It can be activated or deactivated during setup, and the volume level can also be adjusted to suit the enviroment. If the feature is activated, the alarm will sound whenever the cab pressure drops below the preset minimum pressure level for more than ten seconds. It automatically self-resets when the cab pressure returns to normal or when a off/on power cycle is completed.
3 Numeric Display: This indicates the realtime pressure in the cab. During setup, you can select whether to display units in inches of water column or in Pascal.
4 Power: The unit operates whenever the machine is switched on. There is no separate power switch to turn the Pressure Monitor on or off.
5 Silence Alarm Button: Sometimes it is necessary to open a window or door for more than ten seconds. This will set off the alarm. The alarm signal can be silenced by pushing the button. (Note: the light will remain on until pressure is restored.) The alarm mode is self-resetting when the cab pressure normalizes or with an off/on power cycle. The alarm is again armed and will sound after a ten second pressure drop.
6 Quick Connect Fitting: The included air line attaches here.
7 Electrical Wiring: Connects to any convenient DC voltage connection between 9 VDC and 36 VDC, so the same unit can be installed on a 12 or 24 volt system.
8 Low Voltage Pressure Signal Port: The unit includes a 0 to 5 volt output signal that can stream realtime pressure informtion to an on-board computer. The 1/8-inch mono plug signal port puts out a low power voltage signal that varies with the pressure reading. See Technical Specifications for details.

Our High Standards Meet THEIR Standards too!

Sy-Klone’s Electronic Pressure Monitor System meets or exceeds pressure monitoring device compliance standards for:

  • CE Compliant (EU)
  • Canadian OSHA
  • EN15695 (EU Agricultural Sprayer Cab Category 3-4 Cabs)
  • MSHA underground mining applications (USA)
  • AIOH (Australian Institute of Occupational Hygenists)
  • Health Safety Executive recommended device (UK-AG7, CN8, CN11)

Installs Almost Anywhere!

Pressure monitor installtion photos

Technical Specifications:

  • Operating Pressure Range: 0 to 0.8 Inches H2O (0 to 200 Pa)
  • Display Resolution: 0.01 Inches H2O (1 Pa)
  • DC Input Voltage (self-resetting fuse): Minimum: 9V, Maximum: 36V
  • Current Consumption: Less than 30 mA
  • Operating Temperature Range: -40 F to 140 F (-40 C to 60 C)
  • Enclosure Dimensions: 3.50 x 2.52 x 1.39 inches (88.9 x 64 x 35.2 mm)
  • Mounting Plate Dimensions: 4.52 x 2.52 x 0.11 inches (114.8 x 64 x 2.8 mm)
  • Weight: 0.2 oz. (175 g)
  • Air Tube: 3/16 inches OD; 6 foot length (1.8 m)
  • Default Settings(as shipped from Sy-Klone):
    • Sound: On
    • Volume: Full volume
    • Digital display units: Inches of H20
    • Alarm threshold: 0.08 inches H20 (20 Pa)
  • Low Voltage Pressure Output Signal:
    • 0V @ 0 Inches H2O (0 Pa)
    • 5V @ 0.8 Inches H2O (200 Pa)
    • 20 mA
Pressure Monitor Low Voltage Output Chart
This low voltage output signal chart can be used to calibrate real-time pressure data when sent to a computer or telemetric system.